ABB FPBA-01 Bedienungsanleitung Seite 67

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 126
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 66
Communication
67
7 DPV1_Status_1 (DP-V1 only)
x0x00xxx
Dis_Start_Control (Disable Stop-Bit Control)
0 = Start bit monitoring in receiver enabled
1 = Start bit monitoring in receiver disabled
MSB LSB
WD_Base (Watchdog time base)
0 = 10 ms
1 = 1 ms
Dis_Stop_Control (Disable Stop-Bit Control)
0 = Stop bit monitoring in receiver enabled
1 = Stop bit monitoring in receiver disabled
Reserved
Publisher_Enabled
0 = Slave not operated in DXB Publisher mode
1 = Slave operated in DXB Publisher mode
Fail_Safe. Not supported.
DPV1_Enable
0 = Slave operated in DP mode
1 = Slave operated in DP-V1 mode
Seitenansicht 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 125 126

Kommentare zu diesen Handbüchern

Keine Kommentare