ODVA Output Attributes
This section briefly describes the instances found in the ODVA
AC/DC Drive Profiles output assemblies. Not all attributes listed
here will be supported by all output assembly instances.
Run Forward & Run Reverse (Control Supervisor Object)
These attributes are used to assert run and stop commands to
Control Supervisor Object state machine (see “State” below)
according to the following table.
Table 10. Run/Stop event matrix
Fault Reset (Control Supervisor Object)
This attribute resets a drive fault on a transition from zero to one if
the condition that caused the fault has been cleared.
Net Ctrl (Control Supervisor Object)
This attribute requests that the drive Run/Stop command be
supplied
locally (Net Ctrl = 0) or by the network (Net Ctrl = 1).
Net Ref (AC/DC Drive Object)
This attribute requests that the drive speed and torque references
be supplied
locally (Net Ref = 0) or by the network (Net Ref = 1).
RunFwd RunRev Trigger event Run type
00StopN/A
0
10 Run RunFwd
00
1 Run RunRev
0
10 1 No Action N/A
1 1 No Action N/A
0
1 1 Run RunRev
11
0 Run RunFwd