I-E67-TB82FF-2A February 13, 2002
10
GLOSSARY OF PROGRAMMING TEXT PROMPTS
TEXT STRING DESCRIPTION
3K.BLCO 3 kohm Balco (Temperature Compensation).
4.75K.RTD 4.75 kohm RTD Network.
A GRP Sensor Group A.
AAAAAA Alphanumeric Entry.
ACID Pure Water with trace Acid temperature compensation.
AI-.BLK Analog Input Block where ‘-‘ is the block number.
AI-.FV Analog Input Field Value where ‘-‘ is the block number.
AI-.OUT Analog Input Output value where ‘-‘ is the block number.
AI-.PV Analog Input Process Value where ‘-‘ is the block number.
ANALZR Analyzer State.
AUTO Automatic Temperature Compensation (Nernstian) or Automatic Block Mode Handling.
B GRP Sensor Group B.
BAD.CAL Bad Calibration - Entered values caused the calculated values to exceed maximum
values.
BAD.VAL Bad Value - Entered value exceeded maximum allowable value for the entered parameter.
BASE Pure Water with trace Base temperature compensation.
C GRP Sensor Group C.
CALIBR Calibrate Mode.
CON.CAL Conductivity or Concentration Calibration State.
CONCEN Concentration Analyzer State.
COND Conductivity Mode.
CONFIG Configure Mode.
D.P.POS Decimal Point Position.
DAMPNG Damping of the displayed primary value on the transmitter’s HMI.
DENIED An incorrect security password has been entered.
DIAGS Diagnostics State.
DISABL Disable.
EDT.CAL Edit Calibrate State.
ENABLE Enable.
FF.ID Foundation Fieldbus Identification.
HARD.LK Operation cannot be completed due to Hardware write protection.
H2SO4 Sulfuric Acid.
HCL Hydrochloric Acid.
K1/K25 Conductivity at Temperature to the Temperature Compensated Conductivity at the
reference temperature for Point #1. Points 2 through 6 are represented in the same
manner.
MANUAL Manual Temperature Compensation (Nernstian).
MODIFY Modify Configure State.
NACL Sodium Chloride.
NAOH Sodium Hydroxide.
NEUTRL Neutral.
NEW.VAL New Calibration Value - The PV or Temperature value expected during a One Point or
Temperature Calibration.
NEW.VL.C New Temperature Value in degrees Celsius.
NEW.VL.F New Temperature Value in degrees Fahrenheit.
NO D.P. No Decimal Point is desired.
NO.ICON No Icon is desired in the primary display.
NONE None.
OFFSET Offset Value.
OUT.CAL Output Calibration State.
OOS Out Of Service.
OUTPUT Output Mode.
PASSWD Security Password.
PT 100 Pt100 Ohm RTD.