Changing network settings
39
Changing network settings
Overview
The default IP address of an SREA-01 module is 10.200.1.1. There are two ways to
change the network settings:
1. You can use a crossover Ethernet cable to connect to the device and change the
settings by using the web browser interface of the module.
2. You can use ABB IP Configuration Tool to change the settings.
The ABB IP Configuration Tool is a PC-based configuration utility to set TCP/IP
network settings of SREA-01. This utility has the ability to scan the Ethernet network
for connected SREA-01 devices and let the user set IP address, net mask, gateway,
DNS and hostname for each unit.
Note: Ask your network administrator for the correct network settings and an IP
address for the SREA-01 module.
Changing the network settings by using a web browser
You can access the web pages of SREA-01 for configuration if you connect your PC
directly to the unit and change the network settings of the PC to correspond to the
settings of SREA-01.
Note: Changing the network settings of the PC requires administrative privileges.
1. Connect the PC directly to SREA-01 by using a crossover Ethernet cable.
2. Change the IP address of the PC to the same subnet as SREA-01, for example
10.200.1.2. In Microsoft Windows XP, for example, access Network Connections
and open the Properties page for your local network adapter. Select Internet
Protocol (TCP/IP) and click Properties.